
¡¾ÖйشåÔÚÏ߹㶫ÐÐÇé¡¿ ´÷¶û PowerVault ME4012ʵÏÖ¹ÜÀí×Ô¶¯»¯£¬ÎªÖÕ¶ËÓû§Ìṩǿ´ó¹¦Äܲ¢¼õÇá IT µÄ¸ºµ£¡£½«·ÖÎö¹¤×÷¸ºÔØÐÔÄÜÌáÉý¸ß´ï 78%£¬¿ÉÖ§³Ö AI µÈ¹Ø¼ü¹¤×÷¸ºÔØ¡£½èÖúÒµ½ç׿ԽµÄ½â¾ö·½°¸£¬´Ó±ßÔµµ½ºËÐÄÔÙµ½Ôƶˣ¬ÎªÒªÇóÑÏ¿ÁµÄ¹¤×÷¸ºÔØÌṩ֧³Ö£¬´Ó¶ø¼ò»¯ÄúµÄÊý¾Ý´æ´¢ÐèÇó¡£
½üÈÕÔÚÉ̼ҡ°dellemcÊÚȨ¾ÏúÉÌ£¨¹ãÖÝ)¡±Ìؼ۴ÙÏú£¬ÓŻݼÛΪ39000Ôª£¬ºÃÎïºÃ¼Û£¬ÖµµÃÄúÈëÊÖ£¡¸ÐÐËȤµÄÅóÓÑ¿ÉÖ±½ÓǰÍù¹ãÖÝÊа×ÔÆÇøËÉÖÞ½Öé¶Áú´åÎ÷é¶Â·993ºÅ¾ÛÁú´óÂ¥401Ïêѯ£¬¹ØÓÚ´÷¶ûPowerVault ME4012 ´ÅÅÌÕóÁеĴÙÏúÐÅÏ¢Ò²¿É×Éѯ£¨ÁªÏµÈË£º³Â¾Àí ÁªÏµµç»°£º 18616771678£¨Î¢ÐÅͬºÅ£© QQ£º2531181888 £©¸ÃÉ̼ҡ£
²úÆ·Ãû³Æ | ´÷¶û PowerVault ME4012£¨Ë«¿Ø/6*6TB£© |
ϵͳ֧³Ö | Windows 2019/2016/2012 R2£¬RHEL 8.0/7.4/6.9£¬SLES 12.3£¬VMware 6.7 U2/6.5/6.0£¬Microsoft Hyper-V£¬XenDesktop 7.1 |
´¦ÀíÆ÷ | Ó¢ÌØ¶ûBroadwell-DE´¦ÀíÆ÷2ºË2.2GHz |
ÆäËü²ÎÊý | ÈȲå°ÎÓ²ÅÌ£º6*6TB ¾¼Ãʵ»ÝµÄPowerVault ME4ϵÁд洢¾¹ýרÃŹ¹½¨²¢ÇÒÕë¶ÔSAN/DAS½øÐÐÓÅ»¯£¬¿ÉʵÏÖ¼ò±ãÐÔ²¢ÌáÉýÐÔÄÜ PowerVault ME4ϵÁпÉÌṩ¼ò»¯µÄͳ°üʽÈí¼þÐí¿É£¬°üÀ¨£º Adapt£¨·Ö²¼Ê½ RAID£©£º£¨ÀýÈ綯̬´ÅÅ̳أ©¿ÉËõ¶ÌÇý¶¯Æ÷ÖØ½¨´ÎÊý ¾«¼òÅäÖ㺸ù¾ÝÐèÒª·ÖÅäºÍʹÓôÅÅ̳ØÖеÄÎïÀí´æ´¢ÈÝÁ¿¡£½öÔÚÐéÄâģʽÏÂÌṩ¾«¼òÅäÖà SSD¶ÁÈ¡¸ßËÙ»º´æ£ºÍ¨¹ý»º´æÖ®Ç°¶ÁÈ¡µÄÊý¾Ý£¬ÌáÉýÓ¦ÓóÌÐòµÄÖ´ÐÐËÙ¶ÈIPºÍFCÔ¶³Ì¸´ÖÆ£º½«Êý¾Ý°²È«µØ¸´ÖƵ½È«Çò¸÷¸öλÖ㨰üÀ¨¾µÏñ¾«¼òÅäÖóأ© ¿ìÕÕ£ºÍ¨¹ý¡°Ð´ÈëÊ±ÖØ¶¨Ïò¡±¿ìÕÕÔÚÒâÍâɾ³ý»ò¸ü¸ÄºóÇáËɻָ´Îļþ 3¼¶·Ö²ã£ºÌáÉýÐÔÄÜ£¬Í¬Ê±½µµÍÓ²¼þ³É±¾ ¾í¸´ÖÆ/¿Ë¡£ºÍ¨¹ýÔ´Êý¾ÝµÄÍêÕû¸´ÖƸ±±¾£¬ÊµÏÖÎÞ·ì¾íÖØ¶¨Î»ÒÔ¼°»ùÓÚ´ÅÅ̵ı¸·ÝºÍ»Ö¸´ ¼ÓÃÜ£¨SED£©£º²ÉÓÃÇý¶¯Æ÷¼¶¼ÓÃÜ£¬Î´¾ÊÚȨµÄÓû§ÎÞ·¨Ê¹ÓÃÊý¾Ý£¬¼´Ê¹ÒѴӴ洢ģ¿éÖÐÒÆ³ýÇý¶¯Æ÷Ò²²»ÀýÍ⣨°üÀ¨ÄÚ²¿ÃÜÔ¿¹ÜÀí£© ÐéÄ⻯¼¯³É£ºVMware vSphere¡¢vCenter SRM¡¢Microsoft Hyper-V SupportAssist£ºÌṩÔöÇ¿¹¦ÄÜ£¬´Ó¶øÊµÏÖ×Ô¶¯»¯Î¬»¤¹¦ÄÜ |
²úÆ·µçÔ´ | AC 100-240V£¬50/60Hz |
³¤¶È | 576mm |
¿í¶È | 443mm |
¸ß¶È | 87.9mm |
²úÆ·ÖØÁ¿ | 32kg |
´ó׿Ƽ¼ÓÐÏÞ¹«Ë¾£º
ÊÇDELL TECHNOLOGIESºÏ×÷»ï°é½ðÅÆ½â¾ö·½°¸ÌṩÉÌ£»
ÊÇDELLEMC PowerEdge·þÎñÆ÷²úÆ·ÊÚȨ·ÖÏúÉÌ£»
ÊÇDELLEMC´æ´¢²úÆ·ÊÚȨ·ÖÏúÉÌ£»
ÊÇ´÷¶û¿Æ¼¼¼¯ÍÅDCCÉÌÓÃÇþµÀ´æ´¢²úÆ·¹Ëίµ¥Î»£»
ÔÚÈ«¹úÓÐ6¼Ò·Ö¹«Ë¾ ¡£
´ó׿Ƽ¼£¨ÉϺ££©ÓÐÏÞ¹«Ë¾£¬´ó׿Ƽ¼£¨Î人£©ÓÐÏÞ¹«Ë¾£¬´ó׿Ƽ¼£¨¹ãÖÝ£©ÓÐÏÞ¹«Ë¾£¬´ó׿Ƽ¼£¨ÄϾ©£©ÓÐÏÞ¹«Ë¾£¬´ó׿Ƽ¼£¨º¼ÖÝ£©ÓÐÏÞ¹«Ë¾£¬´ó׿Ƽ¼£¨ÉîÛÚ£©ÓÐÏÞ¹«Ë¾µÈ¡£
´ó׿Ƽ¼ÓÚ2009Äê³ÉÁ¢£¬ÊÇ»îÔ¾ÓÚ»ª¶«µØÇø½ÌÓý¡¢¿ÆÑС¢Ò½ÁÆ¡¢¹«°²ÁìÓò£¬¾ßÓзḻʵ¼ù¾ÑéµÄÐÅÏ¢¼¼Êõ¹«Ë¾¡£¾¹ý¼¸ÄêµÄ·¢Õ¹£¬´ó׿Ƽ¼³É³¤ÎªÒ»¼ÒרҵÏúÊÛ´÷¶û·þÎñÆ÷¡¢´÷¶û´æ´¢Æ÷¡¢´÷¶ûÍøÂç²úÆ·£¬emc´æ´¢¡£²¢Îª¿Í»§Ìá¹©ÍøÂç¹¹¼Ü¡¢ÍøÂç¹æ»®¡¢´óÊý¾Ý½â¾ö·½°¸¡¢ÔƼÆË㡢˽ÓÐÔÆ¡¢»ìºÏÔÆµÈÆóÒµ¼¶¼¯Èº²¿ÊðµÄרҵ»¯¹«Ë¾¡£
2015Äê±»´÷¶ûרÌⱨµÀ£º¡°ÁªºÏ´÷¶ûµÄ´´ÐÂÁ¦£¬´ó׿Ƽ¼ÒѾ³ÉΪ»ª¶«µØÇø´æ´¢×¨Òµ¼¼ÊõÇ¿¡¢Êг¡Êµ¼ù·þÎñÁ¦Ç¿¡¢ÒµÎñÍØÕ¹ÄÜÁ¦Ç¿µÄ¡®ÈýÇ¿¡¯ÐͺÏ×÷»ï°é£¬²»½ö3ÄêÒµÎñÔö³¤´ïµ½900%ʵÏÖÁË×ÔÉíÒµÎñ·¢Õ¹µÄ»ªÀöÉý¼¶£¬¸üΪÐÐÒµÓû§´´ÔìÁ˾޴óµÄIT¼ÛÖµ¡£¡±
¹«Ë¾ÓµÓÐ8λ´÷¶ûÔ³§ÈÏÖ¤¹¤³Ìʦ£¬´÷¶ûÆóÒµ¼¶²úƷרҵ¹ËÎÊ£¬Ô³§×ÊÔ´Ö§³Ö£¬ºÜ´óÓÅÊÆ¡£
¹«Ë¾Îª´÷¶û׿Խ¼¶ºÏ×÷»ï°é£¬emc½ðÅÆ´úÀíÉÌ¡£
2016Ä깫˾ÓÖ±»ÆÀΪ¸ß¼¶³ÉΪ´÷¶û¾«Ó¢¼¶ºÏ×÷»ï°é¡£´÷¶û¾«Ó¢ºÏ×÷»ï°éÊÇ´ÓÈ«¹ú¸ß¼¶±ð¡ª¡ª×¿Ô½¼¶ºÏ×÷»ï°éÖо«Ñ¡24λ³ÉÔ±×é³É£¬2016Äê¾ÙÐÐÊ׽쾫ӢºÏ×÷»ï°éÖÇÏí»ã·å»á£¬´÷¶û´óÖлªÇø×ܲûƳº격ʿÇ××Ô³öÈλ᳤£¬´ó׿Ƽ¼ÅáΰΪÊ×½ì»áÔ±¡£
´ó׿Ƽ¼£¬Õâ3ÄêÈ¡µÃ¿ìËÙÔö³¤£¬±»´÷¶ûÉÌÓÃÆ½Ì¨¡¢ËѺü¡¢ÐÂÀË¡¢ÍøÒס¢·ï»Ë¶à¼ÒÍøÂçýÌ屨µÀ¡£
´÷¶ûME4ϵÁд洢
´÷¶û-EMC¹«Ë¾µÄÈ«ÐÂPowerVault ME4ϵÁÐרÃÅÕë¶ÔÖÐСÐÍÆóÒµÁ¿Éí¶¨ÖÆ£¬Äܹ»ÔÚ15·ÖÖÓÖ®ÄÚÍê³É°²×°¡¢¿ÉʵÏÖ15̨ÒÔÉÏÁª¶¯ÅäÖã¬ÇÒ¿É×÷ΪSANÕóÁлòÕßPowerEdger·þÎñÆ÷µÄÖ±Á¬´æ´¢·½°¸¡£
Óë´ËǰµÄÈëÃż¶PowerVaultÕóÁÐÏà±È£¬ME4ϵÁеÄÇý¶¯Æ÷ÊýÁ¿Ôö¼ÓÁË75%£¬´æ´¢ÈÝÁ¿ÌáÉý122%£¬IOPSÐÔÄÜÔò´ó·ùÔö³¤4±¶¡£
ME4ϵÁй²°üº¬Èý¿î»úÐÍ£¬·Ö±ðΪME4012¡¢ME4024ÒÔ¼°ME4084£¬·Ö±ð°²×°ÓÐ12¿é¡¢24¿éÓë84¿éÇý¶¯Æ÷¡£ÆäÖÐME4012²ÉÓÃ3.5Ó¢´çÇý¶¯Æ÷£¬ÁíÍâÁ½¿îÔò´îÔØ2.5Ó¢´çÇý¶¯Æ÷¡£Çý¶¯Æ÷¿ÉΪSSD»ò1Íò5ǧת´ÅÅÌ¡¢1Íòת´ÅÅÌÒÔ¼°½üÏßÿÃë12 Gbit SAS´ÅÅÌ£¬ÇÒͬʱ֧³ÖÈ«ÉÁ´æÓëÉÁ´æ/´ÅÅÌ»ìºÏÁ½ÖÖÅäÖ÷½Ê½¡£
ÈýÕßµÄ×î´óÔʼÈÝÁ¿·Ö±ðΪ3.1 PB£¨ME4012£©¡¢3 PB£¨ME4024£©ÒÔ¼°4 PB£¨ME4084£©¡£
ÕâЩϵͳ֧³Ö10gig iSCSI¡¢16gig¹âÏËͨµÀÓë12gig SASÁ¬½Ó¡£
Óû§¿ÉÒÔÀûÓÃ×Ô¶¯·Ö²ãÔÚÆäÖзָßÈý¸ö½éÖʲ㣬ͬʱ֧³ÖRAID¡¢·Ö²¼Ê½²Á³ý±àÂë¡¢¾«¼òÅäÖÃÓë¿ìÕÕ¡¢¸´ÖÆ¡¢·Ö¾í¸´ÖÆ£¬ÓëVMware vCenterÓëSRMÏ༯³É£¬ÒÔ¼°Çý¶¯Æ÷¼¶¼ÓÃÜ¡£
ÔÚ³ß´ç·½Ãæ£¬Me4012Óë4024ÊôÓÚ2UÉ豸£¬¶øME4084ÔòÐèÒª5U»úÏä¡£
ÆäͬʱÌṩһÌ×HTML5Óû§½çÃæ£¬ÔÊÐíʹÓÃÕßͨ¹ýÈÎÒâÖÕ¶ËÉϵÄÍøÂçä¯ÀÀÆ÷¶Ô¸ÃÉ豸¼ÓÒÔ¹ÜÀí¡£
ÔÚ¸ßÐÔÄܺ͸ßÈÝÁ¿ÈëÃż¶´æ´¢ÖÐʵÏÖ¼òÒ×ÐÔ
ÀûÓÃÊÊÓÃÓÚÈëÃż¶ SAN ºÍ DAS ¹¤×÷¸ºÔØµÄ PowerVault ME4 ϵÁд洢ÕûºÏÄúµÄ´æ´¢¡£ME4 ϵÁзdz£ÊʺÏÓÚ¼Ó¿ì HPC¡¢Microsoft Exchange¡¢±¸·Ý¡¢VDI ÒÔ¼°¸ü¶àÓ¦ÓóÌÐòµÄÐÔÄÜ¡£ME4 ϵÁй¦Äܹ㷺£¬Ö§³Ö¸÷ÖÖÇý¶¯Æ÷ÀàÐÍ¡¢¶àÖÖÐÒéºÍÈ«°üʽÈí¼þ¹¦ÄÜ£¬ÔÊÐíÑ¡ÔñÁ½¸ö 2U »ò¸ßÃÜ¶È 5U »ù´¡ÏµÍ³£¬²¢ÌṩÀ©Õ¹´æ´¢Ä£¿éÑ¡Ïî¡£
Èà SAN ºÍ DAS ´æ´¢¼òµ¥¡¢¿ìËÙ¡¢¾¼Ãʵ»Ý
PowerVault ME4 ϵÁÐÊÇÈëÃż¶Êý¾Ý¿é´æ´¢ÕóÁУ¬×¨Îª¼Û¸ñÃô¸ÐÐÍ SAN ºÍ DAS »·¾³¹¹½¨ºÍÓÅ»¯£¬ÌṩÄúÆÚÍû´Ó Dell EMC »ñµÃµÄ¼òÒ×ÐÔ¡¢¸ßÐÔÄܺ;¼ÃÐÔ¡£
Dell EMC PowerVault ME4 ϵÁÐΪÖÐСÐÍÆóÒµ´øÀ´Á˸߶˴洢µÄ»ù±¾¹¦ÄÜ ¡ª ¼òµ¥¶øÊµ»Ý¡£ÕâЩ»ùÓÚÉÁ´æµÄϵͳΪ¹ã·ºµÄÒµÎñºÍÔ¤ËãÌá¸ßÁËÓ¦ÓóÌÐòÐÔÄÜ¡£Æ¾½èÆäÁé»îµÄÁ¬½ÓÑ¡ÏPowerVault ME4 ÕóÁÐΪ SAN/DAS ¹¤×÷¸ºÔØÌṩÁËÏÔÖøµÄÓÅÊÆ£¬¾ßÓÐÓÅÒìµÄ IOP¡¢´ó´ø¿í¡¢¹æÄ£ºÍµÍÑÓ³Ù¡£È«°üʽÈí¼þÐͺÅÓÐÖúÓÚ¼õÉÙ OPEX£¬Ìá¸ß²Ù×÷ЧÂÊ ¡ª ʹµÃ ME4 ϵÁÐÄÑÒÔ»÷°Ü¡£Èç¹ûÄúÕýÔÚѰÕÒСռÓÿռäÖеÄÔʼÄÜÁ¦ºÍ¼òµ¥ÐÔ£»Èç¹ûÄúÓгɱ¾Òâʶ²¢ÇÒÐèÒª´æ´¢¿ÉÓÃÐԺͿɿ¿ÐÔ£¬ÄÇô Dell EMC PowerVault ME4 ϵÁУ¨¸ß¶ÈΪ 2U »ò 5U£©·Ç³£ÊʺÏÄú¡£PowerVault ME4 ϵͳּÔÚÒÔÓÅÐãµÄ´ÅÅ̾¼ÃÐÔÌṩÉÁ´æµÄÐÔÄÜ£¬ÊʺÏÓÚС¹æÄ£´æ´¢ÕûºÏ¡¢Ó¦ÓóÌÐò¼ÓËÙºÍÒµÎñÁ¬ÐøÐÔ¡£
Ö÷ÒªÌØÐÔ
PowerVault ME4 ϵÁÐΪÖÐСÐÍÆóÒµ´øÀ´Á˸߶˴洢µÄ»ù±¾¹¦ÄÜ ¡ª ¼òµ¥¶øÊµ»Ý¡£ÕâЩ»ìºÏϵͳΪ¹ã·ºµÄÒµÎñÓ¦ÓóÌÐòÌá¸ßÁËÓ¦ÓóÌÐòÐÔÄÜ¡£Æ¾½èÆäÁé»îµÄÁ¬½ÓÑ¡ÏME4 ÕóÁÐΪ SAN/DAS »·¾³ÌṩÁËÏÔÖøµÄÓÅÊÆ£¬¾ßÓÐÓÅÒìµÄ IOPS¡¢³öÉ«µÄ´ø¿íºÍ¿ÉÀ©Õ¹ÐÔ¡£È«°üʽÈí¼þÐͺÅÓÐÖúÓÚ¼õÉÙ OPEX£¬Ìá¸ßÔËӪЧÂÊ ¡ª ʹµÃ ME4 ϵÁÐÄÑÒÔ»÷°Ü¡£Èç¹ûÄúÏëÔÚÓÐÏ޵ĿռäÖÐѰÇóÔʼÄÜÁ¦ºÍ¼«Ö¼òµ¥ÐÔ£»Èç¹ûÄúÓгɱ¾Òâʶ²¢ÇÒÐèÒª´æ´¢¿ÉÓÃÐԺͿɿ¿ÐÔ£¬ÄÇô Dell EMC PowerVault ME4 ϵÁУ¨´Ó 2U »ò 5U »ù´¡ÏµÍ³Æð²½£©·Ç³£ÊʺÏÄú¡£
Ö÷ÒªÌØÐÔ£º
¡¤ 320,000 IOPS ÐÔÄÜ
¡¤ 5500 MB/s ´ø¿í
¡¤ °²×°ºÍÅäÖýöÐè 15 ·ÖÖÓ
¡¤ Ó¢ÌØ¶û® Broadwell ´¦ÀíÆ÷
¡¤ È«°üʽ¸ß¼¶Èí¼þ¹¦ÄÜ
´÷¶ûSC ϵÁд洢
´÷¶û¶ÔÆìÏÂÐԼ۱ȼ«¸ßµÄSCϵÁÐÖж˴洢ÕóÁнøÐÐÉý¼¶£¬ÒýÈë¸Ã¼Û¸ñÄÚ´÷¶û´æ´¢Ç°ËùδÓеÄÓÅÊÆÐÔÄÜ
È«ÐÂSCv3000ϵÁвúÆ·¾ßÓÐÏȽøµÄ×Ô¶¯·Ö²ã¡¢Êý¾ÝѹËõÒÔ¼°ÓëSCϵÁÐÆäËü²úÆ·È«Ãæ¸´ÖƼ°ÁªºÏµÄ¹¦ÄÜ
ÓëÏÖÓеÄÈëÃż¶²úƷϵÁÐSCv2000Ïà±È£¬È«ÐÂϵÁÐÌṩ¸ß³ö3±¶µÄ´ø¿í¡¢2±¶µÄÄÚ´æºÍ50%µÄIOPS
´÷¶ûÈ«·½Î»µÄÆóÒµ¼¶¹¦ÄÜÒýÈëÆäSCϵÁÐÈëÃż¶Öж˴洢²úÆ·£¬Îª²»Í¬¹æÄ£ºÍÔ¤ËãµÄÆóÒµÓû§ÌṩǰËùδÓеÄÏȽø´æ´¢¼¼Êõ¡£¸ßÐԼ۱ȵÄÈ«ÐÂSCv3000ÕóÁÐÍêÉÆÁËÕû¸öSCϵÁвúÆ·µÄ¸üУ¬´øÀ´Á˸ü¸ßµÄ×Ô¶¯»¯¡¢¼¯³ÉÐÔ£¬ÒÔ¼°¸ü¶àÓë¸ü´óÐÍSCϵÁвúÆ·ÏàͬµÄ¹¦ÄÜ¡£
´÷¶ûÈëÃż¶Öж˴洢²úÆ·SCv3000ϵÁдîÔØÁ˼¸ºõÈ«²¿µÄSC²Ù×÷ÏµÍ³ÌØÐÔ£¬°üÀ¨Í³Ò»µÄÁ÷¶¯Êý¾Ý¹ÜÀí¼Ü¹¹¡¢¸ß¼¶´æ´¢¹¦ÄÜÈí¼þ¡¢Ò×ÓõIJÙ×÷¹ÜÀí·½Ê½¡¢¾Ã¾ÑéÖ¤µÄSCOS7²Ù×÷ϵͳÒÔ¼°×¨ÒµµÄ·þÎñÌåϵ֧³Ö£¬ÕâÐ©ÌØÐÔÒѾ¾¹ýSC9000¡¢SC7020ºÍSC5020µÈ¸÷ÀàÖж˴洢Óû§µÄ¹ã·º²ÉÓá£È«ÐÂSCv3000ϵÁвúÆ·ËùÌṩµÄй¦ÄܰüÀ¨£º
Êý¾Ý·Ö²ã¹ÜÀí¡ª¡ªÍ¨¹ý¡°0-100%ÉÁ´æ¡±ÅäÖõÄÁé»îÐÔ´øÀ´Äܹ»ÊµÏÖÕæÕý×Ô¶¯·Ö²ãµÄ»ìºÏÐÍÉÁ´æ½â¾ö·½°¸
ÖÇÄÜѹËõ¡ª¡ªÔÚËùÐèÈÝÁ¿ÄÚ×î¸ß¿ÉÌṩ93%µÄѹËõ
ÓëÆäËüSCϵÁÐÕóÁÐÖ®¼äµÄÈ«Ãæ¸´ÖƼ°ÁªºÏ¡ª¡ªÍ¨¹ýÄÚÖ÷ÏßͼÀ´Âú×ã²»¶Ï±ä»¯µÄÐèÇ󣬴Ӷø±£ÕÏÓû§Í¶×Ê
ÊµÊ±Ç¨ÒÆ¡ª¡ªÎÞ·ìÊý¾ÝÇ¨ÒÆºÍ¸ºÔؾùºâ£¬ÎÞÐè¶îÍâ³É±¾
»î¶¯¾í¡°Ë«»îÌØÐÔ¡±¡ª¡ªÔÚÒâÍâå´»ú»òÔÖÄÑ·¢Éúʱ£¬Îļþ¾íµÄ×Ô¶¯¹ÊÕÏÇл»¼°×Ô¶¯ÐÞ¸´¹¦ÄÜ¿ÉÏû³ý¹¤×÷¸ºÔØÖжÏ
PSϵÁУ¨EqualLogic£©¼¯³É¡ª¡ª¿çƽ̨¸´ÖƺÍͳһ¹ÜÀíÈÃPSϵÁУ¨EqualLogic£©Óû§¿ÉÒÔÇáËɵؽ«SC²úÆ·Ìí¼Óµ½ÏÖÓл·¾³ÖÐ
°´Ðè¼Æ·Ñ¡¢¾«¼ò¿Ë¡¡¢Ô¶³Ì¸´ÖÆµÈÆäËüÓÅÖÊ·þÎñ
¸ü¸ßµÄÐÔÄÜ
ÓëÈëÃż¶ÏµÁÐSCv2000Ïà±È£¬È«ÐÂSCv3000Ó²¼þƽ̨Ҳ½øÐÐÁË´ó·ùÉý¼¶¡£SCv3000ϵÁдîÔØÁËÈ«ÐÂ6ºËÓ¢ÌØ¶û?´¦ÀíÆ÷£¬¾ß±¸ÓëSCv2000Ïà±È¸ß³ö2±¶µÄÄÚ´æºÍ3±¶µÄ´ø¿í£¬Ê¹ÐÔÄÜÌáÉýÁË50%£¬²âÊÔÏÔʾIOPS×î¸ß¿É´ï270,000´Î¡£
Áé»îµÄ²¿ÊðÑ¡Ïî
SCv3000ÕóÁпÉÓÉÓû§×ÔÐа²×°£¬½µµÍ²¿Êð³É±¾£¬Í¬Ê±Óû§»¹¿ÉÏíÊÜÈ«ÃæµÄProSupportºÍProDeploy·þÎñ£¬°üÀ¨¡°Plus¡±°æ¡ª¡ªÒÔ¼°ÐµÄOptimize¸ß¼¶·þÎñÑ¡Ïî¡£
Óû§¿ÉÔÚÁ½¿î×îлù´¡ÕóÁÐÐͺţ¨SCv3000ºÍSCv3020£©Öжþѡһ£¬ÔÚÈý¸ö×îпÉÑ¡À©Õ¹»úÏ䣨SCv300¡¢SCv320ºÍSCv360£©ÖÐÈÎÑ¡ÆäÒ»¡£Í¨¹ýÈÎÒâ×éºÏ¹Ì̬ӲÅÌÒÔ¼°´«Í³µÄ3.5Ó¢´çºÍ2.5Ó¢´çÓ²ÅÌ£¬Óû§¿ÉÒÔ»ìºÏ´îÅäÕâЩ¹¹½¨Ä£¿éÀ´½øÐв¿Ê𣬵¥¸öÕóÁÐ×î¸ß¿É´ï1PB¡£Óû§»¹¿ÉʹÓþßÓÐǰհÐԵĸºÔؾùºâÖ¸ÄϺͻùÓÚÏòµ¼µÄ¸ßËÙ¹¤¾ß£¬ÒÔ½«»ìºÏÕóÁзÖ×éµ½¡°´æ´¢Áª°î¡±¼¯ÈºÖС£
ÕýÈçÆäËüSCϵÁвúÆ·Ò»Ñù£¬SCv3000ϵÁÐÀ©´óÁË´÷¶ûÓ²¼þÓëÈí¼þ¼¯³ÉµÄ±ß½ç£¬°üÀ¨¶ÔVMware vSphere²å¼þºÍVMwareVirtual VolumesµÄÖ§³Ö¡£´÷¶û¶ÔÊý¾Ý±£»¤¡¢´æ´¢¹ÜÀíºÍ¿ÉÓÃÐÔ²úÆ·£¨°üÀ¨Data Domain¡¢PowerPath¡¢RecoverPoint¡¢VPLEX¡¢ViPRµÈ£©µÄÖ§³ÖʹÓû§¿ÉÒÔÈ·ÐÅ£¬ÔÚ²»¶Ï±ä»¯µÄÉú̬ϵͳÖУ¬SCv3000ÕóÁÐÄܹ»¼ÌÐøÍÆ¶¯»ìºÏ¹¤×÷¸ºÔصķ¢Õ¹£¬ÒÔ°ïÖúËûÃÇ˳ÀûÏìÓ¦µ±Ï¼°Î´À´µÄÒµÎñÑݱ䡣
¾¼Ãʵ»Ý£¬ÎﳬËùÖµ
Ô¤ËãÏÞÖÆÎªºÎ¾¹»á×è°Äú»ñµÃÒ»Á÷´æ´¢¼¼Êõ£¿È«ÐµÄSCv3000ϵÁÐÕóÁÐÔÚÈëÃż¶»ìºÏ½â¾ö·½°¸ÖÐÈÚÈë¸ü¶àÒÔÍùûÓеĸ߼¶¹¦ÄÜ£¬ÖúÁ¦Ð¡ÐÍÆóÒµÓÐЧÌá¸ß¾ºÕùÁ¦£¬³ÉЧ×ã¿É±È¼ç¹æÄ£¸ü´ó¡¢³É±¾¸ü¸ßµÄ²¿Êð¡£
SCv3000³õʼ³É±¾¿°³ÆÒµ½ç¼«µÍ ¨C µ«ÐÔÄܸü³öÖÚ£¡Õâ¿îÕóÁбíÏÖ³öÖÚ£¬ÐÔÄÜÔ¶³¬Í¬Àà²úÆ·£¬½«Ò»ÏµÁй¦ÄܶÀÌØµØ½áºÏÔÚÒ»Æð£¬¿É°ïÖú×¢ÖØÔ¤ËãµÄ¿Í»§¼ÓËÙʵÏÖÒµÎñ³É¹û¡£
³öÉ«µÄ»ìºÏÐÔÄÜ
¡°0-100 %ÉÁ´æ¡±¼Ü¹¹ÐÔÄÜÇ¿´ó£¬×î´óÿÃëÊäÈëÊä³ö´ÎÊý(IOPS)³¬¹ý270,000´Î£¬´ø¿í³¬¹ý19,000 MB/Ã룬ÿ¸öÕóÁÐÔʼÈÝÁ¿¶à´ï1 PB* - Ϊ´¦Àí¶à¸öÒªÇó¿Á¿ÌµÄ¹¤×÷¸ºÔØÌṩÁ˷dz£³ä×ãµÄÔ¤Áô¿Õ¼ä¡£
×ÔÎÒÓÅ»¯Ðͼܹ¹
×Ô¶¯ÎªÄú½ÚÔ¼³É±¾£¬ÀûÓÃÊýÁ¿¸üÉÙ¡¢¼Û¸ñ¸üµÍµÄÇý¶¯Æ÷À´»ñÈ¡¸ü¶à¼ÛÖµ¡£¶à²ãÊý¾Ýµ÷¶È¡¢RAID·Ö²ãºÍÖÇÄÜѹËõ¹¦ÄÜ¿ÉÖ÷¶¯½µµÍ³õʼ³É±¾ºÍÉúÃüÖÜÆÚ³É±¾¡£
ÃæÏòδÀ´µÄͶ×Ê
SCv3000×÷Ϊ¹ã·º²úÆ·×éºÏµÄÒ»Ô±£¬ÎÞÂÛÊÇÏÖÔÚ»¹ÊÇδÀ´£¬¶¼¿ÉÒÔ°ïÖúÄú²»¶ÏÍêÉÆ»·¾³£¬ÈÃÄúºÁÎÞºó¹ËÖ®ÓÇ¡£SCϵÁÐÁªºÏ/¸´ÖÆ¡¢Ç¿´óµÄDell EMC²úÆ·Ö§³Ö¡¢µÚÈý·½ÑÜÉú²úÆ·¡£
ÐÂÔö¹¦ÄÜ
ÓëÉÏÒ»´úSCv2000Ïà±È£¬SCv3000ÊÇSCϵÁÐÈëÃż¶²úÆ·ÔÚ¹¦ÄÜÉϵÄÒ»´Î¾Þ´ó·ÉÔ¾¡£
¡¤ ¸ü¿ìµÄÓ²¼þƽ̨ ¨C IOPSÔö¼Ó50 %ÒÔÉÏ¡¢ÈÝÁ¿Ôö¼Ó50 %ÒÔÉÏ¡¢´ø¿íÔö¼Ó3±¶ÒÔÉÏ¡¢¿ìÕÕÔö¼Ó2±¶ÒÔÉÏ¡£*
¡¤ È«ÃæµÄSCOS¹¦Äܼ¯ ¨C ÓëSCv2000²»Í¬£¬SCv3000Ö§³Ö¿É½ÚÔ¼³É±¾µÄÍêÕûSCOS 7Èí¼þ¹¦ÄÜ£¬°üÀ¨Data Progression¡¢ÖÇÄÜѹËõ¡¢Live Migrate¡¢Live Volume¡¢ÓëÆäËûSCϵÁÐÕóÁеÄÁªºÏ/¸´ÖÆ¡¢Thin Clone¡¢ÆóÒµ¼¶µ÷Åä¡¢¼ÓÃÜ¡¢DCB¡¢VvolµÈ¡£
¡¤ Dell EMC¼¯³É ¨C ¹ã·ºµÄVMwareÖ§³Ö¡¢PowerPath¡¢Data Domain¡¢RecoverPoint¡¢Networker¡¢VPLEX¡¢ViPRºÍеÄCloudIQ·ÖÎö¡£
ΪÔÚÏßÓ¦ÓóÌÐòÌṩ¸ü¸ßµÄIOPS¡£ÎªÊý¾ÝÍÚ¾òÓ¦ÓóÌÐòÌṩ¸ü¸ßµÄ´ø¿í¡£Îª¿Í»§ÌṩËùÐèµÄ¸ü¶àÉú̬ϵͳ֧³Ö¡£ÎÞÂÛÄúÔËÐÐʲôÑùµÄ»ìºÏ¹¤×÷¸ºÔØ£¬Õâ¿î¶ÀÌØµÄÈëÃż¶ÕóÁж¼¿ÉÒÔ´ÓÈÝÓ¦¶Ô¡£´ËÍ⣬µÃÒæÓÚ×ÔÓÅ»¯µÄSCOS¼Ü¹¹£¬ÄúÖ»Ð輫µÍµÄ³õʼ³É±¾ºÍÉúÃüÖÜÆÚ³É±¾¼´¿É»ñµÃÕâЩ¹¦ÄÜ¡£
SCv3000ϵÁÐÐͺÅ
»ù±¾ÕóÁÐÌṩÁ½¸ö3U¡°Ò»Ìåʽ¡±ÅäÖá£Á½ÖÖÐͺŶ¼Å䱸Á½¸ö´øÓÐ6ºËÓ¢ÌØ¶û´¦ÀíÆ÷µÄ¿ØÖÆÆ÷¡¢32 GBÄڴ棨ÿ¸ö¿ØÖÆÆ÷16 GB£©ÒÔ¼°Áé»îµÄ10 Gb iSCSI¡¢12 Gb SAS»ò16 Gb FCÍøÂçÁ¬½ÓÑ¡Ïî¡£
¡¤ Scv3000 - 16¸ö3.5"Çý¶¯Æ÷²å²Û
¡¤ Scv3020 - 30¸ö2.5"Çý¶¯Æ÷²å²Û
¿ÉÑ¡µÄÀ©Õ¹Å̹ñÖ§³ÖÀ©Õ¹µ½¶à´ï222¸öÇý¶¯Æ÷£¬»òÿ¸öÕóÁÐ1 PB*£¨ÔÚÁªºÏ¶àÕóÁÐϵͳÖоßÓиü´óµÄºáÏòÀ©Õ¹Ç±Á¦£©¡£ËùÓÐÈý¸öÀ©Õ¹Å̹ñ¾ù¿ÉÓëÈÎÒ»»ù±¾ÕóÁÐÅäºÏʹÓá£ËùÓÐÕóÁкÍÀ©Õ¹Å̹ñÐͺŶ¼Ö§³Ö¶àÖÖ¹Ì̬ӲÅÌÒÔ¼°15K¡¢10KºÍNLSASÇý¶¯Æ÷£¨°üÀ¨¾FIPSÈÏÖ¤µÄSED£©¡£
¡¤ Scv300 - 12¸ö3.5"Çý¶¯Æ÷²å²Û£¬2U
¡¤ Scv320 - 24¸ö2.5"Çý¶¯Æ÷²å²Û£¬2U
¡¤ Scv360 - 60¸ö3.5"Çý¶¯Æ÷²å²Û£¬4U
4:1È«ÉÁ´æ´æ´¢Ð§Âʱ£Ö¤
ÔÚÈκÎÅäÖã¨È«ÉÁ´æ¡¢»ìºÏ´æ´¢ºÍÓ²ÅÌ£©ÖУ¬SCϵÁÐÕóÁж¼·Ç³£¸ßЧ£¬µ«ÎÒÃÇÖªµÀÐí¶àÆóÒµÔÚ²¿ÊðÈ«ÉÁ´æÕóÁÐʱ¶¼Ìرð¹Ø×¢¿ªÖ§¡£Îª´Ë£¬ÎÒÃÇΪËùÓÐÈ«ÉÁ´æSCÅäÖÃÌṩÓб£Ö¤µÄ4:1ЧÂÊ£¬Ïû³ýAFAËù´øÀ´µÄ·çÏÕ¡£Dell EMC³Ðŵ£¬¶ÔÓÚÄúËù¹ºÂòµÄÇý¶¯Æ÷µÄÎïÀíÈÝÁ¿£¬ÎÒÃǵÄÈ«ÉÁ´æÕóÁн«ÌṩÖÁÉÙËı¶µÄÓÐЧÂß¼´æ´¢ÈÝÁ¿¡£
dell´æ´¢ÏµÁÐ
SCv3000 Ë«¿Ø 7*4TB 6**00Ôª
SCv3020 Ë«¿Ø 7*1.2TB 6**00Ôª
SC5020 Ë«¿Ø 12*1.8TB 13**00Ôª
SC7020 Ë«¿Ø 18*1.8TB 19**00Ôª
MD3800F Ë«¿Ø 1*4TB 3**00Ôª
MD3820F Ë«¿Ø 4*4TB 4**00Ôª
ME4012 Ë«¿Ø 4*4TB 4**00Ôª
ME4024 Ë«¿Ø 4*1.2TB 4**00Ôª
ME4084 Ë«¿Ø 84*8TB 24**00Ôª
emc´æ´¢ÏµÁÐ
Unity300 9*2TB 11**00Ôª
Unity400 12*2TB 15**00Ôª
Unity350F 10*400GB SSD 15**00Ôª
Unity450F 10*400GB SSD 20**00Ôª
Unity550F 20*800GB SSD 30**00Ôª
¹ºÂòʱÌá¼°ZOLÖйشåÔÚÏß»á»ñµÃ¸üºÃµÄ·þÎñ»òÓÅ»Ý
¹Ù·½Î¢²©£º@ÖйشåÔÚÏß-¹ãÖÝÕ¾
¹Ø×¢Öйشå-¹ãÖÝÕ¾¹Ù·½Î¢ÐÅ£ºZOL_GZ£¬»ñÈ¡¸ü¶à×ÊѶ£¡
[²úÆ·Àà±ð] ´÷¶û ´ÅÅÌÕóÁÐ
[Æ·ÅÆÐͺÅ] ´÷¶û PowerVault ME4012
[¹Ø ¼ü ´Ê] dell´æ´¢,dell´ÅÅÌÕóÁÐ,´÷¶û´æ´¢,´÷¶û´ÅÅÌÕóÁÐ,´÷¶û´ÅÅÌÕóÁÐME4012,dell´ÅÅÌÕóÁÐME4012,dell ME4012,´÷¶ûME4012,dell ME4012´ÅÅÌÕóÁÐ
[²Î¿¼¼Û¸ñ] 39000
[ÏúÊÛÉ̼Ò] dellemcÊÚȨ¾ÏúÉÌ£¨¹ãÖÝ£©
[ÁªÏµÈË] ³Â¾Àí
[É̼ҵ绰] 18616771678
[ÁªÏµ QQ] 2531181888
[΢ ÐÅ] 18616771678
[µêÆÌµØÖ·] ¹ãÖÝÊа×ÔÆÇøËÉÖÞ½Öé¶Áú´åÎ÷é¶Â·993ºÅ¾ÛÁú´óÂ¥401
[ÍøµêÁ´½Ó] //s.zol.com.cn/shop_89238/34146406.html
С±àÌáÐÑ£ºÍø¹ºÓзçÏÕ£¬Ç뾡Á¿µ½ÊµÌåµêÊÔ»ú£¬Èç±ØÐëÍø¹ºÇëÑ¡ÔñÖ§¸¶±¦¡¢²Æ¸¶Í¨µÈ½»Òׯ½Ì¨½øÐн»Ò×£¬Çë½÷É÷ʹÓûõµ½¸¶¿îµÈ²»°²È«µÄ½»Ò×·½Ê½¡£Çë´ó¼Ò±£ÁôºÃÓÐЧµÄ½»Ò׼Ǽ¡¢Í¨ÐżÇ¼¡¢QQ¼Ç¼µÈ£¬ÒÔ±¸Î¬»¤×Ô¼ºµÄÈ¨Òæ£¡
±¾ÎÄÊôÓÚÔ´´ÎÄÕ£¬ÈçÈô×ªÔØ£¬Çë×¢Ã÷À´Ô´£ºDELL´æ´¢me4012me4024me4084 39000Ôª//gz.zol.com.cn/744/7441343.html